Welcome to our websites!

Bottom price Graham Personnel Services Drug Test - Liquid And Solid Cold Sealing Additive For Anodizing – ZheLu


Product Detail

Product Tags

Related Video

Feedback (2)

We have a minimum capacity of 500KG medium frequency furnace, electric furnace, etc. for aluminum plants with small output, and there are also fixed large-scale aluminum melting roads with a capacity of 5UST to 88UST, for aluminum casting plants with larger output. Anodizing Chemials, Aluminum Heatsink Extrusion, Aluminum Scrap Melting Furnace, Extrusion process: The Billets are to be heated and cut to short before entering the extrusion press machine Extrusion ram push the short aluminum billet into container and through the extrusion die. Then aluminum profile comes out, and pulled by the puller tractor, conveyed on cooling table,heated by aging furnace. Finally through surface treatment such as powder coating or anodizing, the aluminum profile product is finished.
Bottom price Graham Personnel Services Drug Test - Liquid And Solid Cold Sealing Additive For Anodizing – ZheLu Detail:

1. Excellent resistance to impurities and good buffering capacity to acid and alkali.

2. The solution has advantages of easy to operate, a wide range of process parameters, no need to adjust the pH frequently.

3. Prevent the sealing boom from happening.

4. After the sealing treatment, it can improve the surface hardness and gloss of aluminum profiles.

Cold Sealing Additive Deionized water
5~5.5g/L Balance

Ni2+

F-

pH

Temperature

Time

Consumption

0.9~1.3g/L

0.4~0.6g/L

5.5~6.5

22~28℃

1μm/1.3min

0.9~1.5kg/T

1. Determine the concentrations of Ni,F and pH, make them within the range of the process parameters
2. Regulate the pH by adding dilute acetic acid (dilute hydrofluoric acid) or dilute sodium hydroxide (dilute ammonia),keep pH value between 5.5 and 6.5.
3. For reducing the pollution of the rinsing bath solution, control the water quality and pH of the rinsing bath strictly,the pH can not less than 4.5.

Cold Sealing Additive is sealed with polybag, 5kg net each and 4 polybags in carton, 20kg net each. Protected from light in a dry place.

Determination of nickel ion (Ni2+) content
1. Assay steps.
Accurately draw 10mL of the sink liquid into a 250mL triangular beaker, add 50mL of water, 10mL (pH=10) of chloramine buffer, a small amount of 1% violetine, and shake well. Titrate with 0.01mol/L EDTA standard solution until the solution changes from yellow to purple as the end point, and record the consumption volume V.
2. Calculation: Nickel(g/L)=5.869 × V × C
V: the volume of EDTA standard solution consumed in milliliters (mL)
C: molar concentration of EDTA standard solution (mol/L)

1. Preparation of F- standard solution
① Standard solution with F- concentration of 5g/L: Accurately weigh 11.0526g NaF (Analytical Reagent, dry in an oven at 120°C for 2h, store in a desiccator with a weighing bottle for use, accurate to 0.0001g when weighing) to dissolve In a small amount of distilled water, transfer to a 1000mL volumetric flask, dilute to the mark, and shake well.
② Standard solution with F- concentration of 0.1g/L: Pipette 10mL of the standard solution with F- concentration of 5g/L in the above volumetric flask into a 500mL volumetric flask, dilute to the mark, and store in a polyethylene bottle.
③ Prepare standard solutions with F- concentrations of 0.2-1 g/L as described above.

2. Preparation of Total Ionic Strength Adjusting Buffer Solution (TISAB)
Take about 500mL of distilled water and put it in a 1L clean glass beaker, add 57mL of glacial acetic acid, and then add 58.5g of sodium chloride and 12g of sodium citrate to fix and dissolve completely, and then use analytically pure sodium hydroxide to adjust to pH=5.0~5.5, dilute to 1L with distilled water.

3. F- Standard curve drawing
① Pipette 2mL of standard solution with a concentration of 0.1g/L into a 100mL plastic beaker, then add 20mL TISAB buffer solution, put in a magnet, stir on a magnetic stirrer, insert oxygen electrode and reference electrode respectively, After electromagnetic stirring for 3min, stand for 30s, and read the equilibrium potential Ex;
②Use the same method to measure the potential value Ex of the standard solution whose F concentration is 0.2~1g/L, and sort the concentration from low to high. On the graph paper, draw the E-F standard curve with the potential E as the ordinate and the F concentration as the abscissa.

4. Determination process
Accurately pipette 20mL of the sink liquid into a 100mL beaker, add 20mL of total ionic strength buffer (TISAB), stir on a magnetic stirrer for 3min, and directly measure the potential difference mv with a fluorine electrode. Find the corresponding fluorine content m in the fluorine content-potential difference standard electrode diagram .
Process parameters

Cold Sealing Additive Nickel ion Fluoride PH temperature
0.9~1.3g/L 0.4 – 0.6g/L 5.5-6.5 22 ~ 28℃

Product detail pictures:

Bottom price Graham Personnel Services Drug Test - Liquid And Solid Cold Sealing Additive For Anodizing – ZheLu detail pictures


Related Product Guide:

Adhering to the concept of treat sincerely and keep improving, we are promoting the development of aluminum industry over the world. Bottom price Graham Personnel Services Drug Test - Liquid And Solid Cold Sealing Additive For Anodizing – ZheLu , The product will supply to all over the world, such as: Congo, Hamburg, Vancouver, Aluminum extrusion molding (or aluminum extrusion) is a plastic working method that applies strong pressure to the aluminum billet placed in the mold cavity (or extrusion cylinder), forcing the aluminum billet to produce directional plastic deformation and extrude from the die hole of the extrusion mold, so as to obtain the required cross-sectional shape, size and certain mechanical properties of the parts or semi-finished products.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Modesty from Istanbul - 2017.03.28 12:22
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Frank from Madras - 2017.09.16 13:44